DV15 Worstation Features |
General Alarm Processing |
The alarm has been secured in the field
The alarm point has been acknowledged by the operator
The appropriate action has been taken to resolve the alarm
|
Alarm Processing and Reporting |
Device type
Location
Priority
System
Type
Function
Other information, as required
When the alarm was activated
When the alarm was acknowledged
Who acknowledged the alarm
When the alarm was restored
What action the operator took in response to the alarm
What commands the operator issued
Where commands and acknowledgments were entered
|
E-mail Interface |
Alarm inputs changing state to alarm, ‘normal’, open circuit or closed circuit
Alarm inputs isolated or overridden
Outputs on or off
Doors held open
Doors forced open
Doors opened or unlocked
Valid/ Invalid card
Valid/Invalid Access
Individual device type (e.g. SMS controllers, HLIs, LAN and the like) communications failures and restores
Alarm input occurrence count reaching a predefined figure since last reset
Control output, including Door Controller outputs, activation count reaching a predefined figure since last reset
|
Graphical Display |
A Site plan showing all buildings and locations of all alarm points and remote interface panels
Map of the MEH perimeter showing all Perimeter Detection System (PDS) zones, icons, camera selection icons, zone selection icons and the like
A separate graphical map for the site vehicular and pedestrian entry points
A plan for each building
A plan of each floor, and separate area
A plan of each floor, the number of maps per floor shall be sufficient to allow clear display of all areas, devices and device status
All access control and intruder detection devices/status/alarms/etc
All tamper communications, power and the like devices/status/alarms/etc
Other maps shall clearly display all alarm inputs within buildings or external equipment cubicle locations
A Site plan showing all buildings and locations of all alarm points and remote interface panels
Map of the MEH perimeter showing all Perimeter Detection System (PDS) zones, icons, camera selection icons, zone selection icons and the like
A separate graphical map for the site vehicular and pedestrian entry points
A plan for each building
A plan of each floor, and separate area
A plan of each floor, the number of maps per floor shall be sufficient to allow clear display of all areas, devices and device status
All access control and intruder detection devices / status / alarms etc
All tamper communications, power and the like devices / status / alarms etc
Other maps shall clearly display all alarm inputs within buildings or external equipment cubicle locations
A Site plan showing all buildings and locations of all alarm points and remote interface panels
|
|